Ventilation Systems for Laboratories and Cleanrooms
In laboratories and cleanrooms, the indoor air is critical to process reliability and quality. Particles, contaminants, and pollutants must be controlled; defined pressure conditions must be maintained; and temperature and humidity must be reliably regulated. HANSA develops customized HVAC systems for these purposes - tailored to the specific application, cleanliness requirements, and processes.
Typical Applications
Pharmaceutical Manufacturing and Filling
Controlled environmental conditions help protect sensitive products and processes from particles and contamination.
Research and Biotechnology
Defined air conditions and coordinated supply and exhaust air concepts create suitable conditions for sensitive research and development processes.
Chemical and Biological Laboratories
Controlled supply and exhaust air, along with appropriate filtration and safety systems, help protect employees and the surrounding environment from released substances.
Semiconductor and Electronics Manufacturing
Low particle concentrations and stable temperature and humidity conditions are essential for sensitive manufacturing processes.
Optics, laser, and precision engineering
Constant environmental conditions and controlled air purity support precise manufacturing, measurement, and testing processes.
Battery Production and Battery Technology
Depending on the process, very low humidity levels, high purity requirements, special exhaust air concepts, or additional safety requirements may be necessary.
What are the key considerations for air handling units in laboratories and cleanrooms?
Air Purity and Contamination Control
Particles and other contaminants can adversely affect products, samples, and sensitive processes. Filtration, air changes, and airflow must therefore be tailored to the specific application and—in the case of cleanrooms—to the required cleanliness class.
Pressure Conditions and Airflow
Controlled positive and negative pressures, as well as pressure cascades, help prevent the unwanted transfer of substances or particles between different areas. Whether an area is operated at positive or negative pressure relative to its surroundings depends on the specific containment strategy.
Temperature and Humidity
In many laboratory and cleanroom applications, defined air conditions serve not primarily to ensure comfort, but to ensure process and product quality. In addition to narrow temperature and humidity ranges, very low relative humidity may be required, for example, in battery production.
Hazardous Substances and Exhaust Air
In laboratories, gases, vapors, aerosols, or other substances can impose specific requirements on exhaust air, filtration, and material selection. Supply and exhaust air systems must therefore be tailored to the substances used and the respective risk assessment.
Control, Monitoring, and Documentation
Air conditions and pressure conditions must not only be reliably established but also continuously monitored in many applications. Temperature, humidity, differential pressure, airflow rates, and system status can be recorded and documented to ensure stable process conditions in a traceable manner.
Custom HVAC Solutions for Laboratories and Cleanrooms
The requirements in laboratories and cleanrooms vary considerably. Consequently, the design of the equipment can also vary significantly. HANSA works with you to customize the design of the air handling units based on airflow patterns, outdoor air requirements, exhaust air, heat loads, and the necessary process conditions.
Air Handling Units for Laboratories and Cleanrooms
Recirculating Air Units
Where large volumes of air are required for filtration, temperature control, or humidity control, a significant portion of the air can be circulated in recirculation mode. The units can be equipped with high-performance filters as well as additional treatment stages for cooling, heating, humidification, or dehumidification. These units are configured and designed to meet highly specific requirements.
Typical applications: high recirculation volumes, particle control, stable temperature and humidity conditions.
Check out our ReCool Line or Free Line units for this purpose
HVAC Units with Heat Recovery
When supply and exhaust air are routed together through an air handling unit, various heat recovery systems are available depending on the application and intended use. The appropriate system depends, among other factors, on air volumes, energy requirements, and the permissible heat transfer between the air streams.
Possible systems: plate heat exchangers, rotary heat exchangers, or combined circulation systems, as illustrated by our Blue Line unit configuration
Separate supply and exhaust air units with a heat recovery system
If supply and exhaust air must be consistently kept separate, separate units can be energetically coupled via a run-around coil system. Heat transfer occurs via a fluid circuit without the airflows being combined.
etaHydro can be used for the hydraulic connection and efficient control of the heat recovery system.
Supply and Exhaust Air Units Without Heat Recovery
Not every application requires heat recovery. For cooling, exhaust air, or process applications, supply and exhaust air can be handled without energy coupling. Depending on the application, recirculation mode with a variable outdoor air fraction is also possible.
Especially with high heat loads, a large outdoor air flow rate can be used for free cooling and heat removal, while the recirculated air fraction is controlled based on climatic conditions; e.g., if the outdoor air temperature is no longer sufficient for free cooling, the system must switch partially or completely to recirculation mode, and the recirculated air must then be cooled. Additional air treatment stages such as filtration, cooling, or dehumidification can be integrated into the unit.
Units from the HANSA Free Line,for example, are suitable for such individually configurable applications.
Customized Air Treatment for the Process
The unit design provides the framework—the requirements of the specific process are the deciding factor. Filtration, temperature, humidity, and air volume can each impose very different requirements independently of one another. HANSA therefore combines the necessary air-handling stages on a case-by-case basis within the respective HVAC concept.
Filtration and Air Purity
Depending on the application, various filter stages—including particulate filtration—can be integrated. The filter concept, filter arrangement, and airflow path are tailored to the required air purity and the specific process.
Heating and Cooling
Temperature conditions can be precisely controlled using heating and cooling coils. Cooling can be provided via an external chilled water system or—depending on the unit design—via an integrated cooling system.
Humidification
Where defined minimum humidity levels or narrow humidity ranges are required, various humidification systems can be integrated into the air handling system. The selection and control depend on the process and air quality requirements.
Dehumidification
Various methods are available for dehumidification. A classic solution is condensation dehumidification, which involves cooling the air below the dew point and then reheating it.
For processes with particularly low humidity requirements, desiccant rotors can be used. This is relevant, for example, for certain applications in battery production.
Materials and Corrosion Protection
Depending on the process and the substances involved, housings, internal components, and heat exchangers can be manufactured from various materials and designed to meet different corrosion protection classes. Stainless steel, aluminum, or special coatings may also be used on a project-specific basis.
Control and Process Integration
The individual air-handling stages must work together as a complete system. Using its own control and electrical cabinet technology, HANSA can regulate temperature, humidity, pressure conditions, and airflow rates as needed and integrate the air-handling system into the higher-level building or process control system via appropriate interfaces.
Why HANSA?
Custom Manufacturing Instead of Standard Configurations
Laboratory and cleanroom applications have very diverse requirements. HANSA can tailor unit dimensions, airflow patterns, materials, and components to specific projects and combine different air-handling stages into a customized solution.
Experience with Demanding Process Conditions
From laboratory and cleanroom applications to battery production, HANSA has already implemented HVAC solutions for demanding and highly diverse process conditions. This experience is incorporated into the design and engineering of new systems.
In-House Control and Electrical Cabinet Technology
The unit, electrical cabinet, and control system are coordinated as a complete system. This allows even complex requirements for temperature, humidity, pressure conditions, and airflow rates to be integrated within a single control strategy.
Special requirements? We’ve got you covered.
Special materials, high corrosion protection, ATEX-compliant designs, specialized filter concepts, or redundancy requirements can be taken into account right from the design phase and component selection.
Experienced Commissioning
Especially with complex process plants, on-site fine-tuning is crucial for ensuring the quality of subsequent operation. Our experienced commissioning engineers commission both the equipment and the control system together and adjust the relevant operating parameters to suit the plant.
Good to Know
In laboratories and cleanrooms, ventilation and air-handling systems are often determined to a much greater extent by process, product, or safety requirements. In addition to temperature and air quality, particle concentration, humidity, pressure conditions, and the safe removal of contaminated air can be critical factors.
For this reason, the unit design, air treatment, and control systems are tailored to the specific application—often in a much more customized manner than with traditional comfort ventilation.
Controlled positive and negative pressures help to precisely regulate airflow between different areas. Positive pressure can protect a sensitive cleanroom area from particle ingress. Negative pressure, on the other hand, can prevent contaminated air from a laboratory from entering adjacent areas.
When multiple areas are involved, pressure cascades can be established. The specific pressure conditions required are determined by the respective protection and process design.
In laboratories and cleanrooms, temperature and humidity are often important for more than just comfort. They can have a direct impact on product quality, measurement results, or production processes and must therefore be controlled reliably.
Special requirements exist, for example, in certain areas of battery production, where very low humidity levels may be necessary. Depending on the required conditions, either conventional refrigeration dehumidification or sorption dehumidification methods may be used.
Cleanrooms are classified according to the permissible concentration of airborne particles. ISO 14644 serves as an essential normative basis for this. However, the required cleanliness class is determined by the specific process—not the other way around.
For HVAC design, this has a direct impact on the filter concept, air volumes, airflow patterns, and, where applicable, the required recirculated air flow rates.
Stable process conditions can only be assessed if relevant parameters are reliably measured. Depending on the application, parameters such as temperature, humidity, differential pressure, flow rates, and system status can be monitored and documented over extended periods of time.
With etaConnect and etaVisu, the corresponding operating data can be centrally recorded, visualized, and analyzed. This supports operations and service while also ensuring traceability in the event of process deviations or quality issues.
Not looking for an HVAC unit for cleanrooms or laboratories? Then why not take a look at our other application areas: